Here is a list of common error messages that will stop ingestion in CIM, and the user action required to continue.
CIM Ingestion Error Message | User Action Required |
File (or the first worksheet) is empty. | Pipe tally needs to be on the first tab of the excel workbook, adjust & reload the file. |
System identified multiple odometer columns. | Delete one odometer column & reload the file. |
System identified column missing for either orientation or depth. | Add the missing orientation or depth value & reload the file. |
System identified an unexpected error on ingesting values. |
Contact support@onebridgesolutions.com |
System identified an odometer gap larger than 25000 feet. | Adjust the ILI file to remove the gap & reload the file. |
System identified a depth value greater than one, value must be less than one. | Adjust the depth value & reload the file. |
System identified one or more null, blank, or non number values for odometer. | Adjust the odometer values & reload the file. |
System identified that an odometer value is not a numerical number. | Change to a numerical value & reload the file. |
System identified an error when converting orientation values. |
Contact support@onebridgesolutions.com
|
System identified that an orientation value is out of range (0-360) |
Adjust the orientation value & reload the file. |
System identified an unexpected error on ingesting orientation values. |
Contact support@onebridgesolutions.com |
System identified an unexpected elevation value. |
Adjust the elevation value & reload the file. |
System identified percent depth units in header, but data is out of range (0-100). | Remove the percent depth units from the header & reload the file. |
System identified an unexpected error on ingesting depth value. |
Contact support@onebridgesolutions.com
|
System did not find unit for the depth column, and cannot convert to depth fraction. | Add units for depth column & reload the file. |
System identified the file contains no welds, must contain welds to ingest. | Include the welds in the pipe tally & reload the file. |
System identified a depth value less than zero, value must be greater than zero. | Adjust the depth value & reload the file. |
System identified a null, blank, or non number value for orientation. | Adjust the orientation value & reload the file. |
System identified an invalid orientation value. | Adjust the orientation value & reload the file. |
System identified a metal loss row with a depth value out of range (0-1). | Adjust the row value & reload the file. |
System identified a metal loss row with an orientation value out of range (0-360) | Adjust the orientation value & reload the file. |
System identified a weld with repeated odometer values. | Remove the repeated odometers & reload the file. |
System cannot ingest the file. |
Contact support@onebridgesolutions.com |